Daylight factor: interior illuminance under the CIE standard overcast sky as a percentage of the simultaneous unobstructed exterior horizontal illuminance. Feed it the illuminance at each sensor and the exterior illuminance the sky was built for. The ratio is invariant to sky brightness, so the absolute value only has to MATCH the one used for the render — it does not have to be any particular number.
Input
Name
Nickname
Description
Type
Illuminance
E
Interior illuminance at each sensor under the overcast sky, lux.
Number
Sky Illuminance
Esky
Unobstructed exterior horizontal illuminance of the sky the render used, lux. The BRE/CIE convention is 10000; it must match the sky actually rendered.
Number
Target
T
Target daylight factor in percent, for the compliance fraction. BRE's common value is 2 %.
Number
Areas
A
Optional per-sensor areas for an area-weighted average. Leave empty for a regular grid, where every weight is equal anyway.
Number
Output
Name
Nickname
Description
Type
Daylight Factor
DF
Daylight factor at each sensor, percent.
Number
Average
Avg
Mean daylight factor over the grid, percent.
Number
Minimum
Min
Lowest daylight factor on the grid, percent.
Number
Uniformity
U
Minimum divided by average — a space can meet an average target while leaving its depth dark, and this is what shows that.
Number
Above Target
%>T
Fraction of sensors at or above the target, 0-1.
Number
Report
R
The sky, sensor count and target these numbers were produced under.