Set an indoor wall temperature (°C). Wire a room surface to give just that surface its own temperature patch; leave it empty for a single case-wide wall temperature.
Input
Name
Nickname
Description
Type
Temperature
T
Wall temperature (°C).
Number
Surface
S
Optional room surface to give this temperature. Must be part of the room Brep's shell; leave empty to set one case-wide wall temperature instead.
Brep
Name
N
Optional patch name (letters/digits/underscore). Defaults to a positional name.
Text
Power
P
Optional heat load in WATTS this surface emits, instead of a fixed temperature — the nameplate figure for an occupant (~100 W) or a luminaire. OpenFOAM spreads the total over the surface's meshed area, so the wattage stays right however finely it meshes. When set, Temperature is ignored for this wall. A CLOSED Brep (a person, a cabinet) becomes an obstacle carved out of the room with the load on its skin.
Number
Output
Name
Nickname
Description
Type
Wall Temperature
WT
Wall temperature in Kelvin for the Indoor Case component's Wall Temp input.
Number
Wall
W
Named wall patch for the Indoor Case component's Walls input. Only meaningful when a Surface is supplied.