Air conditions on one face of a HAM wall. One value per input is a constant; a list is a stepped schedule (one entry per step, hourly by default).
Input
Name
Nickname
Description
Type
Temperature
T
Air temperature (°C). One value or one per step.
Number
Relative Humidity
RH
Relative humidity (%). One value or one per step. Converted to the vapour pressure hamFoam reads, using the solver's own saturation relation.
Number
Vapour Pressure
pv
Vapour pressure (Pa). Wire this to bypass Relative Humidity — the HAMSTAD cases state their loads this way (case 4's exterior is a constant 1150 Pa while its temperature swings).
Number
Heat Transfer
alpha
Surface heat transfer coefficient α (W/m²K). 25 exterior, 8 interior are the benchmark values.
Number
Vapour Transfer
beta
Surface vapour transfer coefficient β (s/m). 1.8382e-7 exterior, 5.8823e-8 interior are the benchmark values.
Number
Rain Flux
gl
Wind-driven rain reaching the face (kg/m²s). One value or one per step. Interior faces are 0.
Number
Radiation
rad
Absorbed shortwave radiation (W/m²). One value or one per step.
Number
Step
S
Length of one schedule step (hours). Only read when an input is a list.
Number
Output
Name
Nickname
Description
Type
Climate
C
Climate for one side of the HAM Case component.
Generic Data
Vapour Pressure
pv
The vapour pressure actually written (Pa) — one value, or the schedule.