Skip to content

CHT Exterior Air - [source code]

A volume of air that is meshed but never solved: the solids facing it get the surface film set here. Cheaper and steadier than solving a cavity, and the ISO 10211 convention.

Input

Name Nickname Description Type
Geometry G Closed Brep, Mesh or Box of the air volume (model units are metres). Generic Data
Name N Region name (letters/digits, no spaces). Text
Type T What the solids facing this volume see: a convective film, a fixed surface temperature, or adiabatic. Text
Temperature C Ambient air temperature (Convective) or surface temperature (Fixed), in °C. Number
Heat Transfer Coefficient h Film coefficient h (W/m²K), Convective only. ISO 6946: ~7.7 interior, ~25 exterior. Number
Inside Point P Optional point strictly inside the volume. Unwired: derived automatically. Point

Output

Name Nickname Description Type
Exterior E Exterior air for the CHT Case component. Generic Data
Inside Point P The point that names this region's mesh zone. Point