Set an indoor wall temperature (°C). Wire a room surface to give just that surface its own temperature patch; leave it empty for a single case-wide wall temperature.
Input
Name
Nickname
Description
Type
Temperature
T
Wall temperature (°C).
Number
Surface
S
Optional room surface to give this temperature. Must be part of the room Brep's shell; leave empty to set one case-wide wall temperature instead.
Brep
Name
N
Optional patch name (letters/digits/underscore). Defaults to a positional name.
Text
Power
P
Optional heat load in WATTS this surface emits, instead of a fixed temperature — the nameplate figure for an occupant (~100 W) or a luminaire. OpenFOAM spreads the total over the surface's meshed area, so the wattage stays right however finely it meshes. When set, Temperature is ignored for this wall. A CLOSED Brep (a person, a cabinet) becomes an obstacle carved out of the room with the load on its skin.
Number
Output
Name
Nickname
Description
Type
Wall Temperature
WT
Wall temperature (°C) for the Indoor Case component's Wall Temp input. (Kelvin until 2026-10; Wall Temp still reads 150 or more as Kelvin.)
Number
Wall
W
Named wall patch for the Indoor Case component's Walls input. Only meaningful when a Surface is supplied.