Skip to content

Noise Receivers - [source code]

Where the levels are asked for: a ground grid inside a disc at pedestrian height (1.5 m; set 4 m to match an END strategic map), and a point in front of every facade at every storey of the buildings wired in. Facade levels are free-field, without the reflection off the facade they stand before, as CNOSSOS and the END define them.

Input

Name Nickname Description Type
Buildings Bldgs Building solids (Breps, extrusions, meshes) or closed footprint curves. Facade receivers are placed around each; the ground grid leaves out what is inside. Branches are flattened. Geometry
Centre Centre of the study disc. Point
Radius Radius of the study disc, m. Number
Spacing Ground grid spacing, m. 2 m gives ~17,000 points on a 150 m disc; 5 m is a quick look. Number
Height Height of the ground grid above the terrain, m: 1.5 for a pedestrian, 4 for an END map. Number
Storey Height Storey Vertical spacing of the facade receivers, m; the first sits 1.5 m above the building's base. Number
Facade Spacing FacadeSp Spacing of the receivers along each facade, m. Number
Roofs Also place receivers over each roof, at Facade Spacing and Height above it (a roof terrace, a rooftop plant). Boolean

Output

Name Nickname Description Type
Receivers The receiver set, for Noise Run. Generic Data
Ground Points Ground The ground grid, to preview. Point
Facade Points Facades The facade receivers, to preview — drawn on the wall; the receivers themselves stand 2 m in front of it. Point
Roof Points Roofs The roof receivers (when Roofs is on), to preview. Point