Configure simulation control settings for UMF. OutdoorPlus
Input
Name
Nickname
Description
Type
Write Interval
WriteInt
Write interval in time steps. Optional; uses solver default if omitted.
Integer
Write Format
Format
Write format: 'ascii', 'binary', or 'compressed'.
Text
CPU Count
CPU
Number of CPUs/subdomains to use. -1 = auto: sized from the air mesh when one exists (50k cells per core), else physical cores minus two. Optional; default is 1.
Integer
Initial Solid Time Step Factor
SolidStep
Initial solid time step factor for UMF controlDict. Optional.
Number
Min Delta T
MinDT
Minimum time step between iterations. Optional.
Number
Max Delta T
MaxDT
Maximum time step between iterations. Optional.
Number
Min Fluid Iterations
MinFI
Minimum fluid iterations per hourly step before the residual controls may end it. Template default 200: the bulk field of a warm-started hour is stationary by ~150-200 iterations. Optional.
Number
Max Fluid Iterations
MaxFI
Maximum fluid iterations per hourly step (template default 1000). The residual controls normally end a warm-started hour at ~200-300 iterations; the first, cold-started hour needs ~350-500. Optional.
Number
PC Equation Form
PcForm
'pc-based' or 'mixed' (default is pc-based).
Text
Damping Thickness
DampThk
Blending layer damping thickness [m] from the lateral boundaries. Written to the blendingCoeffs block of system/controlDict, which urbanMicroclimateFoam reads only when controlDict 'blending' is true. The case keeps it off (the blending layer looks up patches west/east/north/south; this case's are front/back/left/right), so the value has no effect. Optional.
Number
Alpha Coeff U
AlphaU
Blending layer strength for velocity U (alphaCoeffU). Written to the blendingCoeffs block of system/controlDict, which urbanMicroclimateFoam reads only when controlDict 'blending' is true. The case keeps it off (the blending layer looks up patches west/east/north/south; this case's are front/back/left/right), so the value has no effect. Optional.
Number
Alpha Coeff T
AlphaT
Blending layer strength for temperature T (alphaCoeffT). Written to the blendingCoeffs block of system/controlDict, which urbanMicroclimateFoam reads only when controlDict 'blending' is true. The case keeps it off (the blending layer looks up patches west/east/north/south; this case's are front/back/left/right), so the value has no effect. Optional.