Generate a Markdown report documenting the wind case to the QA discipline of the ASCE/SEI CWE Prestandard (within its steady-RANS pedestrian-comfort allowance): solver and OpenFOAM version, domain and blockage, boundary conditions, numerics and the 2nd-order verdict, mesh quality, convergence, y+, Reynolds, an optional comfort section, limitations, and a compliance summary table. Optionally a scheme comparison (Wind Comfort Compare) and a planning authority's CFD-method checklist with its submission outline (City of London 2019).
Input
Name
Nickname
Description
Type
Case
The wind case — from the Outdoor Case component (full report) or Load Wind Case (reads the case's manifest; cases written before it degrade to what disk carries).
Generic Data
Weather
W
Optional weather record — documents the EPW file, station and location as the study's climate source.
Generic Data
Annual Wind Field
Wind
Optional annual wind speed field from Velocity Amplification Factors — adds per-probe statistics and, with a Metric, the comfort classification.
Generic Data
Comfort Metric
Metric
Optional comfort criterion for the classification table — pick one from the dropdown. The same vocabulary as the Wind Comfort component; an older document wiring the bare enum name (LawsonGeneral) or an index still resolves.
Text
Report Path
Path
Optional .md file path to write the report to — leave it empty and the report goes to '/-report.md', beside the case it describes. Wire or type a path to override that; the folder must exist.
Text
Criteria
Optional criteria object from the Wind Comfort Criteria component; when wired it replaces the Comfort Metric pick in the classification table.
Generic Data
Gust Speed
Gust
Optional annual gust field (Velocity Amplification Factors' Gust Speed output), read by gust-referenced classes such as Wellington's safety class. Without it those classes use mean × 1.85.
Generic Data
Comparison
Cmp
Optional Comparison output of Wind Comfort Compare — adds a scheme-comparison section: scenario matrix, class transitions, significance (City of London tables), receptor usage and mitigation.
Generic Data
Authority
Auth
Optional planning authority whose CFD method requirements the study is checked against — City of London (2019): 1.5 m sampling height, 36 directions, 400 m of context, 0.3 m cells, 10 cells across canyons, 3 prism layers below 1.5 m, no standard k-ε, City Lawson criteria, scenarios. Each line reads Pass, Fail, Incomplete or Not recorded — never a guess — plus the guideline's submission outline.
Text
Write
Write the report to the resolved Path output.
Boolean
Output
Name
Nickname
Description
Type
Report
MD
The whole report as Markdown text.
Text
Path
The file the report will be written to: the autofilled default in the case folder, or Report Path when one is given. Populated whether or not Write has fired, so the destination is visible before it is used.