Thermal Comfort - [source code]

Compute a thermal comfort metric at a point: UTCI (Ta, RH, wind, MRT), PET (adds the personal inputs), NOAA Heat Index (Ta, RH only), outdoor WBGT (Ta, RH, wind at the subject, MRT: ISO 7243 outdoor weighting with the globe temperature derived from the MRT and Stull's wet bulb, as ECMWF thermofeel computes it; bands of the Japanese heat-stroke guideline) or SET* (the Gagge two-node Standard Effective Temperature with the MRT as the radiant field; adds activity and clothing), or Environment Canada's Humidex (Ta, RH) and Wind Chill (Ta, wind; the formula is calibrated on 10 m wind and defined from -50 to 0 °C), or SPMV (Standard Predicted Mean Vote: the EN ISO 7730 vote evaluated at the SET* of the same Ta, RH, wind, MRT, activity and clothing, so solar load and humidity enter through the two-node model). Pick the metric from the dropdown — the inputs adapt. Wire hourly lists (e.g. EPW series) to compute annual values.

Input

Name Nickname Description Type
Metric Comfort metric to compute; the inputs adapt to the choice. Text
Air Temperature Ta Air temperature [°C]. Number
Relative Humidity RH Relative humidity [%]. Number
Wind Speed Wind Wind speed at the subject [m/s]. Number
MRT Mean radiant temperature [°C]. Number

Output

Name Nickname Description Type
Value Metric value [°C]; the dimensionless vote (-3 cold … +3 hot) for SPMV. Number
Stress Thermal stress category. Text
Details Calculation details. Text
Metric Type Metric Metric identifier for metric-aware downstream components such as UTCI Legend. Text