Configure simulation control settings for UMF. OutdoorPlus
Input
Name
Nickname
Description
Type
Write Interval
WriteInt
Write interval in time steps. Optional; uses solver default if omitted.
Integer
Write Format
Format
Write format: 'ascii', 'binary', or 'compressed'.
Text
CPU Count
CPU
Number of CPUs/subdomains to use. Optional; default is 1.
Integer
Initial Solid Time Step Factor
SolidStep
Initial solid time step factor for UMF controlDict. Optional.
Number
Min Delta T
MinDT
Minimum time step between iterations. Optional.
Number
Max Delta T
MaxDT
Maximum time step between iterations. Optional.
Number
Min Fluid Iterations
MinFI
Minimum fluid iterations per hourly step before the residual controls may end it. Template default 200: the bulk field of a warm-started hour is stationary by ~150-200 iterations. Optional.
Number
Max Fluid Iterations
MaxFI
Maximum fluid iterations per hourly step (template default 1000). The residual controls normally end a warm-started hour at ~200-300 iterations; the first, cold-started hour needs ~350-500. Optional.